Product Banner

INT4-I

4-20mA or 0-10V Flow Integrator

The INT4-I accepts 4-20mA or 0-10V signals proportional to flow and calculates the total. The displayed value can be switched between the instantaneous rate and the total. The digital indicator utilises a modular construction technique that enables you to configure it with the exact functionality you require, this flexible approach ensures that you only pay for the features you need.
  • 4-20mA or 0-10V input flow integrator
  • 6 digit display
  • 24V @ 30mA excitation voltage
  • Red or green digits
  • Choice of output options
  • AC or DC powered
Increment Quantity Increment Quantity

Using 4-20 mA or 0-10V signals proportional to flow, the INT4-I calculates the total flow. The value shown can be switched between instantaneous rate and the total rate.

 

Weight N/A
Dimensions N/A
Digit Height

14mm

Displayed Reading

Scalable

Excitation

24V DC @ 30mA

Analogue Output

-10 to +10V, 4-20mA, 0-10V

Alarm Outputs

2 x SPST mechanical relays (AL2), 4 x SPST mechanical relays (AL4), 2 x solid state relays (DSS), 4 x solid state relays (QSS), 2 x mechanical relays (SPCO), 4 x SPCO mechanical relays (4SPCO)

Data Interface

RS232, Modbus RTU, RS422/RS485 + Modbus ASCII

Number of Digits

6

Digit Colour

Red (R)

Digit Colours

Green, Red, Red, Outdoor brightness

Supply Voltage

95-265V AC (AC), 11-30V DC (DC)

Power Burden

10VA maximum

Bezel Size

96mm wide x 48mm high

Panel Cutout

92mm wide x 45mm high

Depth Behind Panel

125mm

Front Panel Sealing

IP65 standard, IP67 with optional SPC4 cover

Operating Temperature

0C to +50 Deg. C

Option ANB

Output: -10 to +10V
Drive Capacity: >1k Ohms
Accuracy: +/-20mV
Resolution: 16 bit D/A, better than 0.2mV

User Manual

Option ANI

Output: 4-20mA
Drive Capacity: <500 Ohms
Accuracy: +/-10uA
Resolution: 16 bit D/A, better than 0.4uA

User Manual

Option ANV

Output: 0-10V
Drive Capacity: >1k Ohms
Accuracy: +/-10mV
Resolution: 16 bit D/A, better than 0.2mV

User Manual

Option AL2

Format: 2 x SPST mechanical relays
Contact Rating: 2A @ 250V AC

User Manual

Option 232

Output: RS232 ASCII

User Manual

Option 485

Output: RS422 / RS485 ASCII and Modbus ASCII

User Manual

Option RTU

Output: RS485 Modbus RTU

User Manual

Delivery

We know you’re excited to receive your order, and we’re working hard to keep parcels moving as quickly as possible whilst also ensuring the safety of our factory and warehouse staff.

Please note, that delivery times are confirmed at the time of order and are estimated, not guaranteed. If you would like to check on the availability and lead time of a particular product, please contact Customer Services at [email protected].

No matter where you are, the size of your order, or how fast you need it – we have a delivery option for you!

UK Mainland Orders:

For current delivery prices please click on the link below. For items not listed in the price list, please request a quote and we will endeavour to provide a price for you as quickly as possible.

https://www.london-electronics.com/pricelists/delivery-within-mainland-uk/

The method of shipment will be at our discretion unless otherwise specified on our acknowledgment. We will however take all reasonable steps to comply with your specific shipping requests

International Orders

At this time we do not accept international payments through our shop. However, no matter where you are in the world we can supply our products to you. Please request a quote through the online form, and a member of our sales team will be in contact with you to discuss further.

Price depends on the delivery location, weight, and value of your order.

Arrange Your Own Collection

You are more than welcome to use your own courier to collect your order if preferred. Alternatively, you can come and see us to collect the order in person.

For either of these options simply select ‘Collect in Person’ or ‘Collect via own Courier’ at the checkout.

It’s safe to say that we’re living through some changeable times right now, so if you’d like to stay up to date with the latest news on how we’re responding, sign up to our newsletter on the link below.

https://www.london-electronics.com/newsletter-sign-up/

 

Using 4-20 mA or 0-10V signals proportional to flow, the INT4-I calculates the total flow. The value shown can be switched between instantaneous rate and the total rate.

 

Weight N/A
Dimensions N/A
Digit Height

14mm

Displayed Reading

Scalable

Excitation

24V DC @ 30mA

Analogue Output

-10 to +10V, 4-20mA, 0-10V

Alarm Outputs

2 x SPST mechanical relays (AL2), 4 x SPST mechanical relays (AL4), 2 x solid state relays (DSS), 4 x solid state relays (QSS), 2 x mechanical relays (SPCO), 4 x SPCO mechanical relays (4SPCO)

Data Interface

RS232, Modbus RTU, RS422/RS485 + Modbus ASCII

Number of Digits

6

Digit Colour

Red (R)

Digit Colours

Green, Red, Red, Outdoor brightness

Supply Voltage

95-265V AC (AC), 11-30V DC (DC)

Power Burden

10VA maximum

Bezel Size

96mm wide x 48mm high

Panel Cutout

92mm wide x 45mm high

Depth Behind Panel

125mm

Front Panel Sealing

IP65 standard, IP67 with optional SPC4 cover

Operating Temperature

0C to +50 Deg. C

Option ANB

Output: -10 to +10V
Drive Capacity: >1k Ohms
Accuracy: +/-20mV
Resolution: 16 bit D/A, better than 0.2mV


Option ANI

Output: 4-20mA
Drive Capacity: <500 Ohms
Accuracy: +/-10uA
Resolution: 16 bit D/A, better than 0.4uA


Option ANV

Output: 0-10V
Drive Capacity: >1k Ohms
Accuracy: +/-10mV
Resolution: 16 bit D/A, better than 0.2mV


Option AL2

Format: 2 x SPST mechanical relays
Contact Rating: 2A @ 250V AC


Option 232

Output: RS232 ASCII


Option 485

Output: RS422 / RS485 ASCII and Modbus ASCII


Option RTU

Output: RS485 Modbus RTU


Accessories

Plain Lens
Once you have programmed the INT4 panel meter and locked out the settings, you can fit this optional plain lens to stop people from being tempted to push buttons. View product
SPC4 Splash Proof Cover
The SPC4 splash proof cover is designed to fit most makes of 1/8 DIN digital panel meters. It increases the front panel sealing to IP67 and provides impact protection. View product
Wall Mounting Enclosure
Our WALLBOX option showing an INT4 panel meter with SPC4 splash proof cover. We can customise by adding pushbuttons, selector switches, LEDs, etc. View product
PCC Cases
The PCC range of cases are great for turning panel mounting meters into portable desktop units. We can customise by adding pushbuttons, selector switches, LEDs, etc. View product
DIN Rail Mounting
Our DIN rail mounting option turns our INT4 panel meters into high precision signal conditioners for mounting inside control cabinets. View product
Dual Wall Mounting Enclosure
The WALLBOX2 allows 2 1/8 DIN panel meters to be placed in a wall mounting enclosure. View product

Applications

A crane overload monitoring and alarm system using INT4 digital panel meters.

A crane overload monitoring and alarm system using INT4 digital panel meters.

A group of INT4 digital panel meters in a batching control panel.

An INT4-C counter mounted on a concrete batching vehicle.
As it is subjected to road spray from the wheels of the truck, it is protected by our IP67 cover. It also has daylight viewing LEDs so that it can be clearly read in sunlight.

A FUSION large digit display with 200mm high digits is summating the loads measured by 6 x INT4-L load cell panel meters.
Summation is digital with data collected over a 3-wire RS485 data link.

10 x INT4 digital panel meters DIN rail mounted inside a control cabinet for a filling line.