Velocity or Speed Digital Panel Meters

More functions in our digital panel meter range ...

 :: 0-10V input panel meters
 :: 1-5V input panel meters
 :: 4-20mA input panel meters
 :: Ampere hour meters
 :: ASCII and T24 input displays
 :: BCD Input, 1/8 DIN, 2 digits
 :: BCD Input, 72x24mm, 4 digits
 :: Check Weigher displays
 :: Clock HH:MM:SS
 :: Counter / totalisers
 :: Depth panel meters
 :: Electro Plating meters
 :: Load Cell panel meters
 :: Loop-Powered panel meters
 :: Plating panel meters
 :: PNP/NPN input meters
 :: Pressure digital displays
 :: Process signal panel meters
 :: Rate panel meters
 :: Resistance panel meters
 :: RPM panel meters
 :: RS232, RS485 input panel meters
 :: Serial data input displays
 :: Speed panel meters
 :: Temperature Sensor displays
 :: Torque Sensor meters
 :: Timer displays - UP or DOWN
 :: Totaliser panel meters
 :: Weighing displays

INT4 digital panel meter pricing



These digital panel meters and controllers are ideal for measuring the speed of objects such as vehicles or projectiles.

Velocity or speed meter




ADEPT-7 velocity meter

ADEPT-7 digital velocity / speed panel meter



cloud based data logger and trend analysis system




The basic model number for this application is:-

ADEPT-7-A-R-M-0-0-0-DI for 110/230VAC power
ADEPT-7-A-R-D-0-0-0-DI for 10-30VDC power

You can add output options such as alarm relays, analogue retransmission, serial data, networking etc, see below...

Application Note:
In applications where there may be muzzle blast, for example if your projectile is fired with explosive, you will need to ensure that the sensors do not detect the blast or you could get a false reading which shows the speed of the muzzle blast rather than of the projectile.

If that is not possible, we make a fast pulse latch module to ensure that only the projectile pulses are passed to the meter. See [here]


Display
Readout 6 LED digits, 7-segment, 14.2 mm (.56"), red or green.
Range -999999 to +999999
Indicators Four LED lamps
Inputs
Types AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups.
Signal Ground Common ground for channels A & B
Channel A Freq. 0 Hz to 1 MHz
Channel B Freq. 0 Hz to 250 kHz
Minimum Signal Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
Maximum Signal 250 Vac
Noise Filter 1 MHz, 30 kHz, 250 Hz (selectable)
Time Interval Mode
Timing Start Channel A pulse, + or - edges
Timing Stop Channel B pulse, + or - edges
Periodic Timing Interval Gate time + 30 ms + 0-2 time intervals
Gate Time Selectable 10 ms to 199.99 s
Time Before Zero Output Selectable 10 ms to 199.99 s
Resolution
0 - 199.999 s 1 ms
0 - 99.9999 s 100µs
0 - 9.99999 s 10 µs
0 - .999999 s 1 µs
0 - .099999 s 0.2 µs
Accuracy
Time Base Crystal calibrated to ±2 ppm
Span Tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year
Power
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power  consumption (typical, base meter) 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Maximum Signal
Max applied voltage 600 Vac for 20, 200 and 300 V ranges, 125 Vac for other ranges
Current protection 25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5 A
Power
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Excitation Output (standard)
5 Vdc 5 Vdc ± 5%, 100 mA
10 Vdc 10 Vdc ± 5%, 120 mA
24 Vdc 24 Vdc ± 5%, 50 mA
Output Isolation 50 Vdc to meter ground
Analog Output (optional)
Output levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable)
4-20 mA, 0-20 mA, 0-10V (dual-output option)
Current compliance 2 mA at 10V ( > 5 kΩ load)
Voltage compliance 12V at 20 mA (< 600Ω load)
Scaling Zero and full scale adjustable from -99999 to +99999
Resolution 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test
Relay Outputs (optional)
Relay types 2 Form C contact relays or 4 Form A contact relays (NO) 2 or 4 Form A, AC/DC solid state relays (NO)
Current Ratings 8A at 250 Vac or 24 Vdc for contact relays 120 mA at 140 Vac or 180 Vdc for solid state relays
Output common Isolated commons for dual relays or each pair of quad relays
Isolation 250V rms working, 2.3 kV rms per 1 min tes
Serial Data I/O (optional)
Board selections RS232, RS485(dual RJ11 or RJ45 connectors), USB, Ethernet
Protocols Modbus RTU, Modbus ASCII, Modbus TCP (Ethernet), LEI ASCII
Data rates 300 to 19200 baud
Digital addresses 247 (Modbus), 31 (LEI ASCII),
Isolation 250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating temperature 0°C to 55°C
Storage temperature. -40°C to 85°C
Relative humidity 95% at 40°C, non-condensing
Protection NEMA-4X (IP-65) when panel mounted





Join our Facebook Group Join our LinkedIn Group Join our Twitter Group



Thorncote Road, Sandy, Bedfordshire, SG19 1PU - ENGLAND
Tel +44(0)1767 626444 Fax +44(0)1767 626446
© 1992-2018 London Electronics Ltd.



ISO9001 certified

Armed Forces covenant
^
^