The Intuitive series of digital panel meter slaves and controllers accept most common ASCII signals such as RS232, RS422 and RS485 and we also have versions to accept T24 wireless data.
INT4-S ASCII data input RS232 or RS485 digital slave display - easy to use!
The INT4-S is our most popular 1/8 DIN panel meter which accepts common serial ASCII data signals such as RS232, RS422 and RS485 and T24.
Precise ...
This digital panel meter is easy to use and can select data to display from complex strings. You can set the display to have 2, 3, 4, 5 or 6 digits, depending on the type of measurement you want to make. You can even scale the numeric value and apply an offset - handy for converting from imperial to meteric, oF to oC etc.
Flexible ...
This panel meter can be fitted with isolated output signal modules to add control and data sharing functions.
Tamper Proof ...
This digital panel meter is also available with a plain front panel. All settings can be locked to prevent changes after commissioning.
The small window in the bottom right can have text such as kg, te, kN, lbs, oC, oF etc.
The display colour is available in red or green.
For hazardous areas we can offer the following explosion proof options on most models. Tell us what you need and we will be pleased to quote for Atex certified systems
Zone 1 ii 2 G Ex px iiC T6/T5/T4 Gb *
Zone 2 ii 3 G Ex nR iiC T6/T5/T4 Gc **
EXD Zone 2 on request - POA
* - Requires pressurised air system
** - any product
The London Electronics ATEX certified products are supplied certified for use in the condition in which they are supplied. No liability will be assumed for any loss or damages of any nature, direct or indirect, including any loss of profits or consequential damages, injury or death suffered or incurred by the buyer as a consequence of failure to install, use and/or apply the product within the scope of the installation document and certification supplied.
INT4-S Specifications
Input connections
Detachable screw terminals.
Input Signal
RS232, RS422, RS485 and T24 (optional). Selectable baud rate, parity and stop bit makeup.
User linearisation
Up to 10 points, direct or theoretical calibration.
Front panel controls
Calibration, Tare, Reset, Max/Min, Alarms
Power
100-240 VAC std, 11-30VDC option. 10VA Power burden, max.
Accuracy
Precisely mimics the incoming data.
Analogue output
Optional plug-in 16 bit module Linearity +/- 0.02% of range
0-20/4-20mA into 0 to 500 Ohms Resolution 0.4uA 0-10V into loads >600 Ohms Resolution 0.2mV -10 to+10V into loads >600 Ohms Resolution 0.4mV
Accuracy 0.1%of range Stability 50ppm/C
Fully isolated from input and power Fully scalable with digital precision
Special features Forward and reverse action possible Can be set to operate from nett or gross value.
Adjustable hysteresis In-flight compensation facility. Energise or de-energise on trip
Special features Adjustable timers to set energise and de-energise delays. Can also be set to pulse for applications needing less than 100% duty cycle. In-band and out-of-band alarm function. Manual and automatic in-flight compensation. Can be set to operate from nett or gross value.
Serial data output
Optional plug-in modules. RS232 RS485 Addressable On demand or continuous output.
Special features Can include time and date with RTC option fitted. Can be set to operate from nett or gross value.
Digits
6 digits, 14mm high. 7 metres max. viewing distance. 10 readings per second. Variable brightness from front panel.
Digit colour
Red - standard. Green - optional
Scaling
Digital menu-free system, direct or theoretical.
In addition, separate Offset and Scale variables allow you to convert the reading, without affecting calibration.
For example from oC to oF, kg to pounds etc.
Excitation
10V DC up to 120mA, to power input sensor. Ratiometric.
Optionally 5VDC