Digital panel meters | Large displays | Bargraphs | Transmitters

4 wire Resistance Meters

[^] Model INT2-R digital 4 wire resistance meter bestseller
The INT2-R is a low cost yet highly precise, stable, flexible and easy to use 1/8 DIN scalable resistance display, and our top seller, for both display-only and display + output applications.

It has a number of useful plug-in options which make it ideal in many control and monitoring applications.

It also has a 10 point linearising function, which lets you correct for non-linearities.

The front panel buttons can be locked, and there is an optional plain front panel with no buttons, which can be put in place of the standard front, after calibration.



Intuitive2-R 4 wire resistance digital panel meter indicator



If you need to be able to read the display in a reflection, for example in a heads-up display system, you can switch it to display a mirrored image.

Interesting fact
The INT2-R is the latest release of this well established display, which was first sold 12 years ago. The fact that it is still a popular seller after all these years is proof that it is 'right' for the job. We designed it, we build it, we know it inside out, so you can count on us for first class support.

Plus...
You can now order this display with digits up to 400mm high! Exactly the same well-proven software and hardware, but with digits of 57mm, 102mm, 150mm, 200mm, 300mm or 400mm high. Ideal for large factories, or anywhere where you need to see your important measurements from far away, inside or outside. The large version is known as the Fusion family, sealed IP65 all round. See here.







manualSee operating Manual (new Mk2 version)
manualSee operating Manual (old Mk1 version)
datasheetSee datasheet
calculatorSee model number & pricing calculator
  
Certified ISO9001:2008            Certified IPC610 Class 2          applications
 
INT2-R Specifications
Approvals Produced to IPC 610 Class 2 Standard

UL ISO9001:2008 QA CERT.
Input connections4 wire.
Input SignalRanges available:
0-2.000 Ohm
50mA excitation, 100mV sense

0-20.00 Ohm
5mA Excitation, 100mV sense

0-200.0 Ohm
50uA Excitation, 10mV sense
ExcitationConstant current depending on range

5mA for 20 Ohm Range, 50mA for 2 Ohm range
Digits6 digits, 14mm high. Legible up to 7 metres away. 10 readings per second. Variable brightness from front panel.
Digit colourRed - standard. Green - optional
ScalingDigital menu-free system, direct.

In addition, separate Offset and Scale variables allow you to convert the reading, without affecting calibration.
FilteringAdjustable 0 to 25 Seconds
Last digit Round-upSelectable 1,2,5,10,20,50
User linearisationUp to 10 points, direct or theoretical calibration.
Front panel controlsCalibration, Tare, Reset, Max/Min, Alarms
Power100-240 VAC std, 11-30VDC option. 10VA Power burden, max.
Accuracy+/-0.1% of range
Thermal stability - range+/- 50ppm/oC
Thermal stability - offset+/- 30ppm/oC
Analogue outputOptional plug-in 16 bit module
Linearity +/- 0.02% of range

0-20/4-20mA into 0 to 500 Ohms
Resolution 0.4uA
0-10V into loads >600 Ohms
Resolution 0.2mV
-10 to+10V into loads >600 Ohms
Resolution 0.4mV

Accuracy 0.1%of range
Stability 50ppm/C

Fully isolated from input and power
Fully scalable with digital precision

Special features
Forward and reverse action possible
Can be set to operate from nett or gross value.
Alarm outputOptional plug-in relay SPST modules
2 Alarms rated 5A 250VAC, SPST
4 Alarms rated 2A 250VAC, SPST
Selectable normally open or normally closed

Optional plug-in relay SPDT modules
2 Alarms rated 5A 250VAC, SPDT

Optional plug-in solid state modules
2 Alarms rated 50V 100mA DC.

Adjustable hysteresis
In-flight compensation facility.
Energise or de-energise on trip

Special features
Adjustable timers to set energise and de-energise delays. Can also be set to pulse for applications needing less than 100% duty cycle.
In-band and out-of-band alarm function.
Manual and automatic in-flight compensation.
Can be set to operate from nett or gross value.
Serial data outputOptional plug-in modules.
RS232
RS485 Addressable
On demand or continuous output.

Special features
Can include time and date with RTC option fitted.
Can be set to operate from nett or gross value.
Logic inputs3 logic inputs, individually configurable for Hold, Reset, Tare, Peak/valley, Nett/Gross, Memory Address

Normally open, NPN or contact closure input to activate.

5V open circuit, 1mA switched current.
Real time clock optionAccuracy better than 2 minutes per year. Allows date and time to be included in serial data, for example for printing time-stamped records.
Automatic summer/winter time correction for Europe and USA

Battery backup to maintain timing whilst switched off. Type = CR1620 3V Lithium
EnvironmentalStorage -20 to +70C
Operating 0 to 50C
Non condensing.
Optional IP67 cover SPC4
ConnectorsDetachable screw terminals
Bezel size96mm wide x 48mm high. 13mm forward.
Panel cutout92mm wide x 45mm high. +1mm, -0mm
Depth behind panel125mm including connectors + cable.
SealingIP65 standard, IP67 with optional SPC4 cover







Resistance measuring panel meter with compensation

The problem...
Many people use resistance meters to check that a coil winding has the correct number of turns, or to check for shorted turns.

The problem is, the resistance of some materials, such as copper, changes with temperature - more than most people realise.

For every 10 deg.C temperature change, the resistance of a coil of copper will change by around 4%. This sensitivity means that normal resistance readings have little meaning in QA applications, unless you monitor the temperature of the resistance.

Let's say you measure the resistance of a copper coil at 30 degrees C.

Assume it reads 5.000 Ohms

At 20 degrees C it would read 4.803 Ohms.

The solution...
We've developed a meter which will compensate for changes in ambient temperature. It gives a constant reading for any given coil, regardless of ambient temperature.

Temperature compensated resistance measurement system

This means you don't need to refer to a chart to correct for temperature changes.

Model INT-R-COMP.
Options include:
Alarm relay outputs (2 or 4 relays)
Isolated analogue output, 4-20mA or 0-10V
Serial data output, RS232 or RS422

Resistance ranges include:

  • 0-10 Ohms
  • 0-25 Ohms
  • 0-100 Ohms

The meter uses a 4 wire connection scheme to eliminate the effects of contact and cable resistance. We normally set the meters to read "Ohms at 25C".



French flag En français...

Contact us

magnificator

Job Vacancies

Home |  Digital panel meters | Large displays | Transmitters | Bargraphs | Message displays |

© 1993 to 2010 Tel +44(0)1767 626444 london-electronics.com Company Registration 2722503
London Electronics Ltd, Thorncote Road, Near Sandy, SG19 1PU, England

valid css